Knowledge/Building Fabric/Floor Screeds in Care Homes: Specification and Common Problems
Building Fabric

Floor Screeds in Care Homes: Specification and Common Problems

Sand-cement, anhydrite and quick-drying screeds -- which to use, how long to allow before floor finishes are applied, and what causes failures.

4 min readCareHomeDesk Knowledge Base

Screed types

In care home refurbishment projects, three screed types are commonly used. Sand-cement screed (BS 8204-1) is the traditional choice -- durable, well-understood and inexpensive, but slow to dry (typically 25mm depth per week of drying time). Anhydrite (calcium sulphate) screeds dry faster than sand-cement and have excellent self-levelling properties, but must not be used in wet rooms or below DPC level. Quick-drying screeds (modified cementitious systems) allow floor finish application within 24-72 hours and are increasingly specified in care home projects to reduce programme time. All screeds must comply with BS EN 13813.

Minimum drying time

Applying a floor finish -- vinyl, tile, carpet or any adhesive-fixed product -- before the screed has dried sufficiently is the single most common cause of floor finish failure. Moisture in the screed will cause vinyl to bubble, adhesive to fail and LVT planks to lift. The acceptable moisture content at the time of floor finish application is typically 75% RH (measured using a calibrated hygrometer in accordance with BS 8201). Do not accept a contractor's assurance that the screed is 'ready' -- measure it. For critical rooms in a care home where disruption is costly, build additional drying time into the programme.

Screed failure in wet rooms

Floor screeds in wet rooms are subject to additional stresses: thermal cycling from hot shower water, cyclic wetting and drying, and mechanical impact from hoists and wheelchairs. Specify a screed with a minimum compressive strength of C25 for wet rooms. A modified screed with polymer additive provides better adhesion to the tanking membrane and better resistance to thermal cycling. If a screed in a wet room begins to crack or de-bond from the substrate, this must be investigated promptly -- the waterproof membrane beneath may be compromised. Do not simply overlay a failed screed without investigating the root cause.

Put this into practice

CareHomeDesk gives you compliance checklists, maintenance logs, and contractor management tools built around exactly this kind of knowledge.

Join the waitlistMore articles

More in Building Fabric

Roof Inspection Guide for Care Home Managers
Types of care home roof, inspection frequency, and how to read a condition survey report.
5 min read →
Damp and Mould in Care Homes
The three types of damp, their causes, and why CQC now treats persistent mould as a safety concern.
5 min read →
Crack Stitching in Care Home Masonry: What It Actually Does and What a Specification Should Cover
Helical bar crack stitching stabilises a cracked wall -- it does not fix why the crack happened. What the standard requires and what to check before work starts.
5 min read →